超聲波流量計(jì)生產(chǎn)公司 0411-87305712

                超聲波流量計(jì)實(shí)時(shí)信息,超聲波流量計(jì)資料下載,超聲波流量計(jì)價(jià)格,相信大連索尼卡—流量測量問題輕松解決。

                « 什么是防護(hù)等級IP65,IP55Handheld Ultrasonic Flowmeter »

                Ultrasonic flowmeter

                Ultrasonic flowmeter   Features
                • Guaranteed lowest price on the market
                • High accuracy: ±1% normally; ±0.5% when on-site calibration available
                • Wide pipe size range (from 1" to 240")
                • Non-intrusive. No pipe disturbance. No moving parts. No pressure drop.
                • Easy and economical installation. No pipe cutting or hole drilling.
                • Easy to use and set up. Self-explanatory menu programming
                • Velocity, volumetric and totalized flow
                • IP65 weather-proof enclosure
                • 4-20mA output, OCT digital output, relay output, batch control, alarm control
                • Isolated RS485 interface, MODBUS compatible
                • Optional GPRS / GSM networking module
                • No maintenance
                • Low power consumption. Less than 1 W
                • Ideal for both clean and opaque liquid flows
                   
                Descriptions :
                The FV2000 General Purpose Wall-Mount Clamp-on Ultrasonic Flowmeter is the first member of the 3rd generation ultrasonic flowmeters from sonic. Compared with the predecessors, the 3rd generation ultrasonic flowmeters offer better performances and a richer feature set, all at a lower price.
                The FV2000 is designed to be installed at a fixed location for long-term flow measurement from outside of a pipe that carries pure liquids and liquids with minor suspended particles. It utilizes cutting-edge technologies such as advanced transducer design, low voltage transmission, digital signal processing, and self adaptation to achieve high performance.
                As QUALITY is of crucial importance, all transducers are carefully paired, and all flowmeters are wet-calibrated in the factory to further ensure system accuracy and reliability.
                FV2000  provides versatile input/output interfaces, such as digital and relay outputs, batch control, alarm, flow totalizing, 4-20mA output, and optional RTD interface for thermal energy measurement, which can be easily used by a host computer or a flow controller for process monitoring and control. Besides, the isolated built-in RS-485 port and the optional GPRS/GSM module make remote flow monitoring easy and reliable.
                Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency and no blockage on the flow. The installation is very simple and requires no special skills or tools. The cost of installation, operation, and maintenance is lower than that of conventional flowmeters.
                FV2000 is an ideal choice for demanding applications where low-cost, high-performance and non-intrusiveness are a must. A pplications include, but are not limited to, liquid process control, water flow measurement (hot/chill water, city water, sea wat beverages, and many other liquids.
                   

                 
                Main Unit
                Repeatability
                Better than  ±0.5%
                Accuracy
                Better than ±1%. Can reach ±0.5 when on-situ calibration is available
                Response Time
                0.5s. 0-99s user-programmable
                Velocity
                 -52ft/s - +52 ft/s (-16m/s - +16 m/s), bi-directional.
                Display
                LCD with backlight.  2 x 20 character display.
                Displays instantaneous flow rate, totalized flow rate, velocity, sound speed, time, analog inputs, etc.
                Units
                English (U.S.) or metric
                Signal Outputs
                Current output: 4-20mA or 0-20mA. Impedance 0-1k. Accuracy 0.1%
                Isolated OCT output: can be programmed as pulse output for flow totalizers or frequency output for flow rate
                Relay: can be programmed  to control alarm, valve or batch process
                Sound alarm
                Signal Inputs
                One channel 4-20mA current input: for signals such as temperature, pressure, liquid level. etc. Accuracy 0.1%. Additional analog input channels are available upon request
                Two RTD temperature channels (refer to model STUF-300R1B): to accommodate two PT100 temperature sensors. Thermal energy measurement and calculation functionalities implemented.
                Recording
                Automatically records the following information:1) The totalizer data of the last 64 days / 64 months / 64 years;2) The power time and corresponding flow rate of the last 64 power-on and -off events; 3) Allows for manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days.
                Communication Interface
                Isolated RS-485. Supports the MODBUS protocol. Optional GPRS / GSM module for networking, remote monitoring and remote control (for model STUF-300FNB only)
                Enclosure
                Protection Class:  IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model STUF-300F2B only)
                Liquids
                Liquid Types
                Virtually all commonly used liquids (full pipe)
                Liquid Temp
                -40?F ~ 312?F (-40?C ~ 155?C), depending on transducer type
                Suspension concentration
                < 20,000ppm. Particle or air bubble size should not exceed 75um
                Pipe
                Pipe Size
                1" ~ 240"For pipe size of 1” and smaller, the STUF-300FxG flow-cell flowmeter is recommended
                Pipe Material
                All metals, most plastics, fiber glass, etc.  Allows for pipe liner.
                Pipe Straight Run
                 15D or longer preferred, where D is pipe diameter.
                If a pump or valve is near upstream, the straight pipe section should be > 30D.
                Cable
                Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines. Neither should it be close to strong interference sources such as power transformers.
                Environment
                Temperature
                Main unit: 0?F - 176?F (-30?C - 80?C)
                Transducer: -40?F ~ 212?F (-40?C ~ 100?C) for the standard version; -40?F ~ 312?F (-40?C ~ 155?C) for the higher temperature version
                Humidity
                Main unit: 85% RH
                Transducer: water-immersible, water depth less than 10’ (3m)
                Power
                AC: 90V / 260V, or, DC: 18VDC-36VDC<1 Watt
                Weight
                Standard main unit: 4 lb (2 kg),   Network main unit: 5 lb (2.5 kg)
                   
                Transducer Options:
                 
                Clamp On Flow Meters
                Type S1
                Small size transducer (magnetic) for pipe size 1” – 4” (DN25 – DN100mm) Note: for pipes of 1” and below, we recommend our flow-cell transducer (Stuf-300FxG.)
                High-temp transducer Type S1HT
                Small size transducer
                high temperature (up to 155°C) for pipe size 1” – 4” (DN25 – DN100mm)  
                Digital Flow Meters
                Type M1
                Medium size transducer (magnetic) for pipe size 2” – 28” (DN50 – DN700mm)
                clamp-on transit-time ultrasonic flowmeter
                Type M1HT Medium size transducer
                high temperature (up to 155°C) for pipe size 2” – 28” (DN50 – DN700mm)  
                Clamp on Ultrasonic Flow Meters
                Type L1 Large size transducer (magnetic) for pipe size 11” – 240” (DN300 – DN6,000mm) 

                • 相關(guān)文章:

                日歷

                最新評論及回復(fù)

                最近發(fā)表

                友情鏈接

                大連索尼卡儀表有限公司

                   地址:大連開發(fā)區(qū)遼河西路155號       銷售部:0411-87305712    0411-87305703     13840933012

                 

                国产的精品无码免费看,一区二区三区av激情电影,国产精品系列无码,国产高清无码一区二区久久